Main Street Feasibility Study

Details

Location

Placerville, CA

COMPLETION DATE

2015

MATERIALS

unreinforced masonry (URM), timber, concrete

ENGINEERING CONSIDERATIONS

Historic preservation, rehabilitation and strengthening of damaged URM building

CLIENT

City of Placerville

KEYWORDS

Commercial, masonry, timber, concrete, retrofit

Description

Burne provided the structural analysis and cost estimates for the City to determine the feasibility of rehabilitating the building. The building is constructed of unreinforced masonry (brick & mortar) and has significant cracks in need of repair and strengthening. The building was originally constructed in 1861. It is a historic building that lends to the charm of the downtown area.